Non-return valve for sewerage: what is it for and when is installation required


Types of check valves

Depending on the type of shut-off element, all check valves are divided into several categories:

  • Ball. The locking element is a plastic or metal ball supported on top by a spring. Under the influence of liquid pressure, the spring is compressed, lifting the ball and allowing liquid to flow into the channel.
  • Rotary. The shutter is made in the form of a folding flap. It opens as the fluid flow moves and closes when it weakens or stops. They are often used in metal pipeline networks that take water from a well or borehole, since they are characterized by low sensitivity to environmental pollution.
  • Disk. The permeability of the pipeline is regulated by a steel disk that can rotate around its axis. In everyday life, their use is justified in networks made of metal-plastic, where contamination of the working environment is minimal.
  • Lifting. In this type of valve, the valve can be moved up or down by a spring. The compression and expansion of the spring occurs under the pressure of the water pressure. It can only be located on horizontal sections of the pipeline, and the valve axis must be oriented strictly in the vertical direction. The advantage of this type of valve is the ability to repair it without removing it from the system.

Non-return valve for sewerage: what is it for and when is installation required

Based on the method of connecting the check valve to the pipeline, the following types of devices are distinguished:

  • Wafer. Mounted between two flanges located at adjacent ends of the pipeline. The valve itself does not have fastening elements. Fixed with bolted connections.
  • Flanged. They are equipped with special connecting elements with sealing gaskets. Like wafer-type ones, they are more often used on large trunk networks.
  • Couplings with thread. More often used in pipeline networks of small diameters. They are secured using threads located on the outer or inner surface of the couplings.
  • With welding fastening. Installation of such valves is carried out by welding. The connection is permanent, so locking elements of this type are used quite rarely, mainly for networks with aggressive working environments.

In addition, check valves can be made of steel, cast iron, brass, polypropylene, etc. In this case, the component parts can be made from different materials. For example, a stainless steel or brass body, a plastic shutter and a steel spring.

Cast iron products are rarely found in everyday life, due to their susceptibility to corrosion and the gradual accumulation of deposits. Their main area of ​​application is main pipelines. Stainless steel devices are almost completely devoid of such disadvantages, but have a fairly high cost.

Polypropylene products are intended for installation in pipeline networks mounted from the same material. Installation is carried out using polyfusion welding.

Non-return valve for sewerage: what is it for and when is installation required

Purpose and principle of operation

The main function that a water check valve performs is that it protects the water supply system from critical flow parameters of the liquid transported through the pipeline. The most common cause of critical situations is stopping the pumping unit, which can lead to a number of negative phenomena - draining water from the pipeline back into the well, spinning the pump impeller in the opposite direction and, accordingly, breakdown.

The installation of a check valve on the water allows you to protect the water supply system from the listed negative phenomena. In addition, the water check valve prevents the consequences caused by water hammer. The use of check valves in pipeline systems makes their operation more efficient, as well as ensures the correct functioning of the pumping equipment with which such systems are equipped.

Non-return valve for sewerage: what is it for and when is installation required

Operating principle of a check valve

The principle of operation of the check valve is quite simple and is as follows.

  • The flow of water entering such a device under a certain pressure acts on the locking element and presses the spring, with the help of which this element is kept closed.
  • After the spring is compressed and the shut-off element is opened, water begins to move freely through the check valve in the required direction.
  • If the pressure level of the working fluid flow in the pipeline drops or the water begins to move in the wrong direction, the spring mechanism of the valve returns the shut-off element to the closed state.

By acting in this way, the check valve prevents the formation of unwanted backflow in the piping system.

Non-return valve for sewerage: what is it for and when is installation required

Spring type check valve with nylon spool plate

When choosing a valve model installed on a water supply system, it is important to know the regulatory requirements that manufacturers of pumping equipment impose on such devices. The technical parameters by which a check valve for water is selected in accordance with these requirements are:

  • working, test and nominal closing pressure;
  • diameter of the landing part;
  • conditional capacity;
  • tightness class.

Information on what technical requirements a water check valve must meet is usually contained in the documentation for the pumping equipment.

Non-return valve for sewerage: what is it for and when is installation required

Single-disc coupling check valve

To equip domestic water supply systems, spring-type check valves are used; the nominal diameter is in the range of 15–50 mm. Despite their compact size, such devices demonstrate high throughput, ensure reliable operation of the pipeline, low noise and vibration levels in the pipeline system on which they are installed.

Another positive factor of using check valves in a water supply system is that they help reduce the pressure created by the water pump by 0.25–0.5 Atm. In this regard, a check valve for water allows you to reduce the load both on individual elements of pipeline equipment and on the entire water supply system as a whole.

Product materials and sizes

When choosing a sewer check valve model, it is recommended to know what materials the device is made of, as well as the dimensions of the products. The most common materials:

  • stainless steel;
  • cast iron alloy;
  • bronze;
  • plastic.

In most cases, a check valve is purchased from the same material as the pipeline installed in an apartment or private building. It is not recommended, for example, to buy a plastic device for cast iron pipes. The most popular choice in terms of price/quality ratio is a valve made of high-quality plastic.

The dimensions of the device depend on the amount of free space. There is also such a characteristic as the connection method - horizontal or vertical. In most cases, devices for horizontal connections are used, but if there is not enough free space behind the toilet, bathtub and other plumbing fixtures, then vertical check valves are installed. If there is critically little space, then it is recommended to purchase a wafer type of mechanism. For its installation, only seals are required.

Photo – appearance of the device

Valve device

Standard valve models are formed by two cylinders perpendicular to each other, which are connected in such a way that a single cavity is created. The ends of these cylinders have different outputs - one is connected to the pump pipe or another water supply channel, and the second is plugged. As a result, a controlled cavity is created, the locking mechanism of which regulates the passage of water flow in one direction. Again, there may be different principles for the operation of this control system, but the standard is considered to be an operating mode in which the open valve condition will correspond to normal operation of the system. Of course, the device parameters may be different. For example, there is a check valve for a water pump provided by a hydraulic accumulator. The design of such models is specifically focused on the possibility of integration between the pumping station and the storage tank, which insures the equipment against water hammer.

Types of check valves

A water check valve may differ in design, material of manufacture, installation features and dimensions. Let's try to classify them according to these distinctive features:

By type of locking element

  • lifting type. The shutter in such a device moves up and down. When water flows from the pump, the valve opens, and when the pressure in the line drops, the valve returns to the closed position under the action of a spring;
  • rotary type. The shutter in such a valve has the form of a flap, which opens when the water moves, and closes under the action of a return spring when the pump is turned off.

    The photo shows a rotary type check valve for water

  • ball type. The shutter in the check valve is a ball that blocks the passage. The ball is supported by a spring. The water pressure lifts the ball, which moves, and allows water to flow into the channel;
  • wafer type. It is divided into disc and bicuspid. A disc check valve for water has a disc valve that can move along its own axis under the action of a spring attached to it. In a double-leaf reverse valve, the shutter consists of two connected flaps that can fold when water passes through, and close when there is no water.

    Double-leaf water return valve

According to the material of manufacture

  • made of brass. This is a reliable, corrosion-resistant material that is durable and easy to maintain. It is considered an ideal material for household use;
  • made of cast iron. This material is used relatively rarely, as it is susceptible to corrosion and gradual accumulation of deposits. Cast iron valves are used on large diameter pipelines. Cast iron valves are not used in everyday life;
  • made of stainless steel. They are devoid of almost all disadvantages. They are durable, resistant to corrosion and aggressive substances, and durable. The price for a stainless check valve for water is the highest, but the quality of such a product is always at its best.

In most cases, the components of a check valve are made of different materials. So, the body can be brass or stainless steel, the shutter is usually plastic, and the spring can simply be steel or stainless. Therefore, when purchasing, immediately ask what materials were used in the manufacture of the valve.

By mounting method

  • coupling fastenings. The vast majority of check valves are attached in this way. For fastening, 2 threaded transitions are used. Their diameter can be completely different, depending on the diameter of the pipeline;
  • flange mountings. They are attached to pipelines using flanges. These are predominantly cast iron valves used on pipelines of very large diameters;
  • Wafer mounts. The valves are mounted between two flanges, which are tightened with bolts. Their use is also limited to pipelines of large diameter.

To size

  • standard valves. Used on most pipelines;
  • miniature products inserted inside water meter outlets. They are used if there is no space on the pipeline to install a standard check valve;
  • small valves installed at the outputs of meters;
  • Large cast iron valves installed on pipelines for public use and industrial purposes.

Types and differences of designs

The tasks of all types of water valves include simplifying plumbing work and protecting against pressure drops in the pipeline, in particular if the operation of the pump is disrupted. In addition, each individual type also has specific tasks, as it is needed in the water main. There are several varieties that make the water check valve multifunctional:

Non-return valve for sewerage: what is it for and when is installation required

Types of water check valves

  • devices with a locking mechanism are divided into ball disk, leaf, spool;
  • divided by type of fixation: wafer, flange, coupling;
  • According to the speed of shutting off the water, the valve can be either slamming or smooth.

Each option has its own individual characteristics, which are important to consider when purchasing. So, a ball valve is a ball spring mechanism

The disc type valve contains a special disc in its structure. Both of these designs are capable of working with the highest water pressure that is permissible for polypropylene pipelines at home. Often such a structure is installed after a pump from a well or other source. Look at the photo to see what the device looks like

So, a ball valve is a ball spring mechanism. The disc type valve contains a special disc in its structure. Both of these designs are capable of working with the highest water pressure that is permissible for polypropylene pipelines at home. Often such a structure is installed after a pump from a well or other source. Look at the photo to see what the device looks like.

Ball check valve for water

The flap device can be used exclusively in pipes with low pressure; spool options are characterized by a spool design, which is the main working element. All these devices are made of brass or polypropylene, and are mainly installed before and after the meter.

A wafer check valve for water is installed in home pipelines strictly using outdated technology, while flanged and coupling versions are bolted or threaded for normal fixation. If necessary, a ball spring operating mechanism can also be used.

The slamming mechanism works instantly when water enters, while the smooth mechanism works somewhat slower, but at the same time maintains a longer service life. The photo will tell you how the mechanism works.

Non-return valve for sewerage: what is it for and when is installation required

Check valve with slam mechanism

Each type of return device can be used both for a water pump and for placement in a working pipeline. Moreover, all valves have separate functional features and are fixed outside the meter.

Is it really necessary?

Installation of a sewer check valve 50 or 110 is not always required; there are certain situations when installing this device does not make much sense. For example, residents of apartments on the 6th floor of an apartment building do not have to worry about possible sewer flooding through the central blockage, because... the pressure of waste fluids will not maintain a high level when rising to the 6th floor.

In general, there are situations when it is strongly recommended to install the device:

  • location of the apartment on the first/second floor of a multi-storey building;
  • location of office space on the first two floors;
  • private 1-storey house;
  • cottage-type country house with 2-3 floors.

In the above situations, it is financially more profitable and easier to install a valve on plumbing fixtures in advance than to later repair the premises and deal with the negative consequences of a clogged and broken sewer. It is especially important to install the mechanism in houses with old pipelines. Pipes in such buildings usually have a layer of sediment on the inner walls, resulting in a smaller working area and an increased likelihood of clogging.

Spring coupling check valve: types by material

Products can be made from different materials:

Non-return valve for sewerage: what is it for and when is installation required

Brass valve body

Non-return valve for sewerage: what is it for and when is installation required

Cast iron body

Non-return valve for sewerage: what is it for and when is installation required

Stainless steel body

Non-return valve for sewerage: what is it for and when is installation required

Universal reverse type device with strainer

Differences in mounting method

Most devices are attached using a coupling. This requires two threaded transitions, which are selected according to the size of the pipeline. Flange type fastenings can also be used. Most often they have cast iron elements of large diameter. Such flanges are tightened with bolts. This type of fixation is also relevant for small products when there is no room on the pipe for other fastening.

Non-return valve for sewerage: what is it for and when is installation required

Flange connection is one of the best options

The spring clutch check valve is the most commonly used. It is used in apartments for installation on a pipeline or water heater; such products are installed after the meter, which does not allow it to spin in the other direction. Devices of this type prevent the pipes from emptying if water drains in the riser.

The structure of the spring mechanism: it consists of a brass body, which can be disassembled into two parts. A movable spool is placed between the halves. It is usually made of plastic. This spool is driven by water pressure and a spring.

Non-return valve for sewerage: what is it for and when is installation required

Spring elements: body and inner part

Related article:

Technical characteristics, diameters and manufacturers

Important technical parameters of the device are:

  1. Diameter. Selected according to pipe dimensions. The diameter can be 5, 7.5 or 11 cm. The first 2 types are installed on intra-apartment systems, the last - on the riser. Some valves can be placed on sewer elements of different sizes. This becomes possible thanks to the introduction of a stepped pipe. On pipes of non-standard sizes, tees with a ventilation valve are installed.
  2. Bandwidth. This parameter reflects the volume of air entering per second. For 1 l/s of wastewater, up to 25 l/s of gas is required. The valve capacity can reach 37 l/s.

In our country you can purchase vacuum valves manufactured by HL (Austria), McAlpine (Great Britain), Wavin (Poland), Europlast (Ukraine), Ostendorf (Germany).

Installation and installation procedure

In order to answer the question of where the valve is installed, you should pay attention to its design features and the availability of free space in the intended mounting area of ​​the device body. The rather delicate moment associated with disconnecting the entire access riser must also be taken into account (this applies to the case when it is planned to install a check valve before the inlet valve of the water supply network)

Non-return valve for sewerage: what is it for and when is installation required

In order to avoid the need to coordinate this issue with neighbors, it is recommended to install the valve device on the water immediately after the valve distributor. The main thing that needs to be taken into account during installation is the direction of normal movement of the drains, which is usually indicated by an arrow marked on the side of the body. In this case, the valve is fixed on the pipe in such a position that the arrow coincides with the direction of the natural flow of waste.

Non-return valve for sewerage: what is it for and when is installation required

Other features of installing a check valve can be presented as follows.

Firstly, the installation of a plastic non-return valve is carried out according to the classical scheme, which involves the use of a standard socket and sealing gasket for this purpose. The working section of such a pipe is joined to the socket with the valve, and the place where they meet is additionally treated with silicone for reliability.

Non-return valve for sewerage: what is it for and when is installation required

Secondly, for the installation of cast iron products, special sealing rubber bands must be used, complete with bolts that reliably tighten the mounting metal plates. At the same time, there are also models on sale equipped with a bell-shaped expander, designed for traditional tow while simultaneously sealing the resulting seam.

When choosing a check valve model suitable for given conditions, special attention should be paid to the presence of a special cover on the body that provides access to the internal parts. 

During installation, you should take into account such an important detail as the location of the inspection hole. For ease of maintenance, free access must be provided to it, allowing, if necessary, to check the internal mechanism or carry out its control cleaning.

How to install it yourself

At the time of design, the risk of flooding should already be included in the system, so during this period it is necessary to work out the installation of the valve. Installation takes place in several stages.

Installation of a check valve can be done both on an external system and on an internal one.

The first stage is choosing an installation location

The location for installing the throttle must be easily accessible. The equipment must not be installed in the wall or floor, covered or cluttered.

Each device has a cover for cleaning and repair, so access to it is required at all times. If the sewerage system runs in the floor or concrete base, the locking mechanism is mounted in the pipe, and its upper part remains on the surface.

If the depth of the gasket is large and the headband is out of sight, we make a removable cover in the floor for inspection.

The second stage is choosing a device

Locks are classified differently, some are installed outdoors, in a well, others can only be installed indoors. It is necessary to choose the most suitable one for the installation conditions. If there is an error at this point, the shutter may subsequently collapse or crack.

Tools:

  1. Grinder with cutting disc.
  2. A sharp, hard knife for chamfering.
  3. Oil, lubrication paste.
  4. Hammer and flat board.
  • At the installation site, we clear the work area.
  • We measure the length of the device so that it fits into the prepared space.
  • Lubricate the end of the pipe generously with motor oil or plumbing paste.
  • The O-ring should also be treated.
  • Before inserting the firecracker into the pipe, having made the socket, we will turn the device several times (if possible).
  • With a little effort, but sharply we stick the pipe into the throttle.
  • Then we check to see if the rubber band in the device has pulled up.
  • On the reverse side we continue assembling the sewerage system.

It is not always possible to install a throttle during the initial installation of the pipeline. This can be done in the current system.

  • Having chosen a place, use a grinder to carefully cut out a piece of pipe. It is advisable to choose a place closer to the socket so that the piece can be removed.
  • We make a piece of pipe slightly larger than the device itself. In order not to disassemble the entire thread, we will need a channel with a compensatory socket.
  • We insert the compensator into the pipe, and the valve from the other edge.
  • We insert the assembly onto the pipeline first from the side of the compensator, moving it until it stops, then, pushing it out of the socket, insert the valve on the other side.

Important: each cut point in the pipe must be processed by chamfering.

How to chamfer a plastic or PVC pipe

The end, if it is not fixed in the system, is pulled out and pressed between the legs or armpit so that the cut is in front of the eyes. Using a sharp knife, we begin to cut the edge in a circle. The result is a chamfer, a cone. We also remove all burrs in the cut areas.

How to place it at the outlet of a plumbing fixture

To install it to the toilet, you will need an external device without a stable housing, inside which the clapper moves. Instead, a cuff is placed on the back of the toilet, with a hard membrane attached to the end. The shutter is of a conical type. A serial connection allows you to insert the device inside the socket, where the plate will work. We coat each joint with oil or plumbing paste for better connection.

Correct and incorrect placement

Each device, open or closed, has the direction of movement of the drains drawn on the body. Indicated by an arrow or triangle. It is in the direction of the water that the water seal is installed.

The shutter only works in one direction and in different positions: whether the device is vertical or horizontal. If all installation conditions are met, in the first minutes it will be clear that the device is functioning and water is passing through the membrane.

Types of check valves, their design and operating principle

The check valve device is simple. There is a slightly tapered seat and a locking element. With the “correct” flow, the shut-off element is pushed away from the bottleneck. As soon as the direction changes, he presses against the saddle, blocking the passage. By the way, there should be an arrow on the body that indicates the “correct” direction of water movement.

Non-return valve for sewerage: what is it for and when is installation required

How a water check valve works and how it works

Basically, check valves are distinguished by the type of shut-off element. He can be:

  • ball type (ball);
  • disc-shaped;
  • disk;
  • petal or bivalve.

In a ball valve, the ball is “free floating”. It is not attached to anything and is transported by water. Quite a reliable system. It’s just that it doesn’t always cover the saddle tightly enough, so it’s used quite rarely.

Non-return valve for sewerage: what is it for and when is installation required

Types of check valves for water

Disc-shaped ones can be lifting or rotating. Rotary, as well as ball, open and close under the influence of water flow. Lifting ones have a spring-loaded rod. In the “normal position” the passage is closed; when water pressure appears, it presses the spring, pushing the locking element upward.

The most common type in home water supply systems is the disc check valve. It differs in that fittings of this type can be small in size. And the design is simple and reliable. The locking disc is placed across the flow and is pressed against the seat by a spring. Water squeezes the spring, clearing its way.

Non-return valve for sewerage: what is it for and when is installation required

A check valve is a device to prevent the reverse movement of the transported medium

There is also a two-leaf valve for water. Its locking element consists of two halves of the disk (petals), which are fixed to the axis. Hence another name for this model - petal. They are held closed by springs. The water entering the water supply system presses them back, folding them and pressing them against each other. This type has the least hydraulic resistance. In some cases (with a long suction line) this may be important.

Operating principle of a check valve

First of all, it should be noted that check valves are not installed “just in case,” but only if necessary, if there is no other technical solution. This is due to the fact that the elements often have considerable hydraulic resistance, depending on the design. This introduces some restrictions when using check valves for heating with natural circulation. The reason is too low coolant pressure in the system.

Despite the differences in design, most products are equipped with one key part - a spring. It is an actuator that closes the valve when normal conditions change; this is the principle of operation of the check valve. The force expended to overcome the elasticity of the spring determines the magnitude of the hydraulic resistance of the mechanism. For circuits with different operating parameters, products are selected that have the appropriate elasticity and massiveness of the spring.

What does the spring act on? Its task is to keep the locking device closed; this is its normal state. Then the fluid flow flowing from one side can overcome the elastic force of the spring, open the obstacle and move further along the pipe. An attempt to change the direction of the flow and flow in the other direction will lead to nothing - the shut-off device will slam shut, relying on the tide in the body. In this place there is a sealing element that makes the check valve in the heating system completely sealed.

Shut-off valves intended for use in heating circuits are made from the following materials:

  • gray cast iron;
  • steel;
  • brass;
  • stainless steel.

Pros and cons of aerators

The positive qualities of the aerator include:

  1. Normalization of sewerage work. Installing an auxiliary part prevents the spread of an unpleasant “aroma” that is dangerous to the human respiratory system.
  2. Possibility of refusing to install a drain pipe. The placement of the aerator allows you to avoid creating an exit in the roof of a private house.
  3. Possibility of installation in a non-ventilated riser. In this case, the valve only works effectively in a low-rise building. In multi-storey buildings, the part is used in combination with a fan structure.

The disadvantages include the possibility of the rod jamming. This is caused by membrane wear or clogging of the aerator. The second is unlikely; debris gets into the case only when the lid is opened.

Rating
( 1 rating, average 4 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]